![hp dl360 g6 smart array setup hp dl360 g6 smart array setup](https://www.idgcdn.com.au/article/images/750x750/dimg/m_img_18050.jpg)
- HP DL360 G6 SMART ARRAY SETUP HOW TO
- HP DL360 G6 SMART ARRAY SETUP INSTALL
- HP DL360 G6 SMART ARRAY SETUP DRIVERS
- HP DL360 G6 SMART ARRAY SETUP UPDATE
- HP DL360 G6 SMART ARRAY SETUP SOFTWARE
HP DL360 G6 SMART ARRAY SETUP INSTALL
Please be sure to install the HP ESXi Offline Management Agent Bundle after you install ESXi. You've asked a few VMWare questions here. This provides many more options for the RAID controller, including detailed definitions of logical drives, granular cache control and a nice GUI to help define the arrays. Following that, download the SmartStart CD to run the graphical Array Configuration Utility. The better option for your system, given that you've just added the controller to an older server, is to download the current bootable HP Firmware DVD to bring all of the system components up-to-date. After the ambient temperature display, you will receive a prompt to "Press any key to view Option ROM messages" - Press any alpha-key on the keyboard at this point.įrom there, you'll see a prompt for the ILO 2 configuration menu and then, you'll receive a few options for your Smart Array controller.
![hp dl360 g6 smart array setup hp dl360 g6 smart array setup](http://maychumang.vn/content/images/thumbs/0011096_hpe-proliant-dl360-g9-sff-e5-2623v4.png)
The "Sea of Sensors" POST routine takes awhile from the first screen prompt (on a warm-boot) to step through RAM checks and to register the sensors. You're going to have to pay close attention to the POST messages in order to catch the RAID controller's ORCA utility prompt.
HP DL360 G6 SMART ARRAY SETUP DRIVERS
However, if you look at the output of the SSH session you'll notice the drivers being used right now aren't the latest drivers.Assuming you're on a recent firmware revision for the D元20 G6 server. Rebooted the server and now indeed the Health Status in ESXi 5.1 (914609) is correct. Maximum configured DDR3 10600R memory is 12 x 16GB up to 192GB.
![hp dl360 g6 smart array setup hp dl360 g6 smart array setup](http://pds23.egloos.com/pds/201201/02/18/a0105618_4f016dff66e84.jpg)
I already ran the latest SPP (Feb 2013) on my server so I've skipped that step. HP Proliant D元60 G6 Configure to Order Server is a 1U dense chassis capable of supporting 12 physical cores of computing performance.We can pack up to 24TB SATA or 19TB of SAS storage in this unit. WAIT! - After you reboot give it a few minutes for health to start being reported - My machine didn't show any health for at least 2 or 3 minutes.
HP DL360 G6 SMART ARRAY SETUP UPDATE
Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.
HP DL360 G6 SMART ARRAY SETUP SOFTWARE
Next SSH to the ESXi server (I did so as root) and run the following command:Įsxcli software vib install -d hp-esxi5.0uX-bundle-1.3.5-3.zip You should put the file inthe following location: IF YOU HAVEN'T ALREADY ENABLED SSH etc on the ESXi box, follow these steps:Ĭopy the file onto your ESXi server (no vCenter, but specific ESXi server) - I user Filezilla using the SSH credentials for root but you can find your own way. THEN, to fix with health warning under ESXi5 U2ĭownload the HP Offline Bundle - The one for my server was found here: You may need to find your own. Run the SPP and update everything - this removed my BIOS 'warning' relating to Drives/RAID Combining improved 1U compute performance, smart power and cooling management with infrastructure management tools and essential fault tolerance, the HP ProLiant D元60 G6 is optimized for space constrained installations. (you should check which is compatibale with your server). (Warning this will not install in a virtual machine, but you can extract the files and run the HPUSBKEY app manually) I downloaded the Proliant SPP and made a USB KEY (using HP USB KEY creator 1.7) but a DVD would have been just as effective. I fixed this in two stages - Firstly my BIOS message.
HP DL360 G6 SMART ARRAY SETUP HOW TO
I hope data on disks are still there but iam not sure how to add them back without erasing them. My problem is that with this step my Smart Array configuration is gone too. Please take the time and effort to check.validate this for yourself. i've got some problem with booting from USB so i decided to load BIOS defaults (option without erasing anything else just bios config) on my HP Proliant Microserver gen8.